KINGSINE K3030i
มีผู้ชม 2656 ครั้ง
Secondary Injection 3 Phase AC Protection Relay Testing Sets K3030i with RJ45 Connection
1. Unique self-protection system assure the powerful protection when instrument is operating, automatic stop the output when the network is abnormal ;
2. Unique power switch and amplifier technology, so the output precision and power efficiency and factor are increased, which conforms to international tendency of energy save and environmental protection;
3. With alarm function of housing grounding testing and external voltage input, to guaranty personal security;
4. Two in one of meter and source, with function of both internal and external testing, self-calibration, oscillograph, and the duration of each oscillograph reaches 50S (optional function);
5. Offer independent Aux. DC to tested devices, 0 ~ 300V/0.6A (Poleless and adjustable);
6. Function of transducer and energy meter testing (optional function);
7. Testing interface offer unique output monitoring function and Pre-curve-tracing function, helps more on the spot analysis;
Technical Data of K3030i
Voltage generators
|
Setting
Range
|
4-phase AC (L-N)
|
4 x 0 ... 300 V
|
|
2-phase AC (L-L)
|
2 x 0 ... 600 V
|
Power
|
4-phase AC (L-N)
|
4 x 110VA, at 0 ... 300 V
|
|
2-phase AC (L-L)
|
2 x 220VA, at 0 ... 600 V
|
Accuracy
|
<0.07% reading + 0.03% range guaranteed
at 0 ... 300 V
<0.02% reading + 0.01% range typical
at 0-300V
|
Resolution
|
1mV
|
Current generators
|
Setting
Range
|
3-phase AC (L-N)
|
3 x 0 ... 30 A
|
|
1-phase AC (2L-N)
|
1 x 0 ... 60 A
|
|
1-phase AC (3L-N)
|
1 x 0 ... 90 A
|
Power
|
3-phase AC (L-N)
|
3x 450VA , at 0 ... 30A
|
|
1-phase AC (2L-N)
|
1x 520VA, at 0 ... 60A
|
|
1-phase AC (3L-N)
|
1 x 1200VA, at 0 ... 90A (Max.)
|
Accuracy
|
<0.07% reading + 0.06% range guaranteed at 0-30A
<0.02% reading + 0.02% range typical at 0-30A
|
Resolution
|
1mA
|
Generators, general
|
Frequency
|
Range
|
0 ... 1000 Hz
|
|
Accuracy / drift
|
Error < 0.001Hz at 10 ... 65Hz,
Error < 0.01Hz at 65Hz...450Hz
Error < 0.02Hz at 450Hz...1000Hz
|
|
Resolution
|
0.001Hz
|
Phase
|
Range
|
- 360° ... +360°
|
|
Accuracy / drift
|
Error < 0.2 °
|
|
Resolution
|
0.1°
|
Timer
|
Range
|
Infinite
|
|
Accuracy / drift
|
Error<0.1ms
|
DC generators
|
Voltage ranges
|
0 ... 300V/150W
|
Current ranges
|
0 ... 20A/300W
|
Accuracy
|
<0.07% reading + 0.03% range guaranteed at 0-300V
<0.04% reading + 0.02% range typical at 0-300V
|
|
<0.14% reading + 0.06% range guaranteed at 0-20A
<0.05% reading + 0.02% range typical at 0-20A
|
Resolution
|
1mA; 1 mV
|
Aux DC Supply
|
Range
|
0...300V/0.6A
|
Binary inputs
|
Number
|
8 pairs
|
Compatible Voltage
|
10V ... 250V DC
|
Binary outputs
|
Number
|
4 Pairs
|
Capacity
|
250V/3A AC/DC
|
Synchronization
|
Synchronization mode
|
GPS
|
Harmonic
|
Harmonic overlap times
|
2 ... 20 times
|
Power supply
|
Nominal input voltage
|
220VAC±20%
|
Power
|
1000VA
|
Nominal frequency
|
47Hz….65Hz
|
Environmental conditions
|
Operation temperature
|
-5°C ... 55 °C
|
Storage temperature
|
-20°C ... 75 °C
|
Humidity range
|
5% ... 90 %, non-condensing
|
Weight
|
20 KG
|
Dimensions
|
460(D)×140 (W)×360 (H) mm
|
PC connection
|